Aller au contenu principal

EVN1700-MBC

Always On. Always Aware.
Carte PCB de remplacement Everon 1700
  • Carte PCB de remplacement pour la centrale Everon 1700
  • Centrale d’alarme Everon 1700, connectivité IP embarquée, conformité EN Grade 3, interface WebApp, 8 zones intégrées (jusqu’à 48 zones), gestion de 4 secteurs.
  • À partir du firmware MR3.2, l’ATS1700 gère jusqu’à 48 zones. Avec un firmware inférieur à MR3.2, la capacité est limitée à 32 zones.
Tout voir

Au premier coup d'oeil

Product overview

Replacement PCB for Everon 1700 panel (ATS1700)
EVN1700-MBC is delivered only with PCB and with associated plastic cover.
For upgrading from ATSx500, also order EVNx700-RETRO fit kit which contains PSU, Brackets and cables etc. needed for upgrading.

Détails

  • Carte PCB de remplacement pour la centrale Everon 1700
  • Centrale d’alarme Everon 1700, connectivité IP embarquée, conformité EN Grade 3, interface WebApp, 8 zones intégrées (jusqu’à 48 zones), gestion de 4 secteurs.
  • À partir du firmware MR3.2, l’ATS1700 gère jusqu’à 48 zones. Avec un firmware inférieur à MR3.2, la capacité est limitée à 32 zones.

Spécifications techniques

System
Product line
Everon
Product type
Integrierte Zugangskontrolle
Panel type
Hybrid
Kit
No
No. of keypads / readers
8
Data Gathering Panels (DGP)
7
No. of alarm groups
256
Specified cable
WCAT52 or equivalent
Inputs
Max no. of inputs
48
Onboard inputs
8
Inputs plug-in expansion
8
ATS1202 support
3
Outputs
No. of outputs
128
No. of onboard outputs
3 electronic outputs + 1 relay
Area
No. of areas
4
User/Cards
Max. no. of users
more than 2000
Users with name
1000
Max. no. of cards
2000 to 65532
Max. no. of PIN codes
2000 to 65532
Access control
Standard doors on control panel
4
Door groups
128
Floor groups
128
Intelligent doors on 4-door DGPs
28
Communication
Onboard transmission type
IP
Transmission extension
GSM
GSM/GPRS
GSM/GPRS/IP
IP
Databus type
RS485
Event log
Alarm event log
14500
Access event log
10000
Electrical
Operating voltage
24 VDC
Mainboard current consumption
110 mA at 24 V (PSU), 160 mA at 12 V (battery)
Max system current
950 mA at 13.8 V ±0.2 V
Max aux power current
2500 mA at 13.8 VDC ±0.4 V
Auto-reset fuses
3 (electrical, 1.3A per use)
Glass break fuses
1 (mains power, T-2A 230 VAC, slow)
Physical
Physical dimensions
199 x 140 x 45 mm
Net weight
435 g
Environmental
Operating temperature
-10 to +55°C
Relative humidity
95% noncondensing
Environmental Class
Class II, indoor
IP rating
IP31
Regulatory
Compliancy
CE
Certification
CE
Supported versions
Version MR3.2 and above supports up to 48 zones; versions prior to MR3.2 supports up to 32 zones